05
Godrej Air Conditioner Showing 05: What It Means
"05" on a Godrej split air conditioner is not an error code. Godrej's own split AC owner's manual (both the edition for model GSC 12ITC3-WUA hosted on godrejenterprises.com and the 2024 wall-mounted split AC owner's manual) covers it in the section headed "IF IT HAPPENS, IT IS NOT A PROBLEM", in the row: "After AC is switched off, if indoor display shows '05' — It may happen that you have selected the BLOW function when AC was ON, and therefore AC is performing BLOW operation after it turned OFF." The remote-controller section of the same manual describes the BLOW button: "If bad odor is coming from the air conditioner, press BLOW button on the remote handset. This function will keep the indoor fan running at super high fan speed for 5 minutes, after this the air conditioner is turned OFF. The indication of minutes will be displayed on the displayer." So 05 is the minute count of that drying run: the AC has been switched off, the indoor fan is running on at high speed to dry the evaporator coil, and the display shows the minutes remaining, starting at 05. The manual adds that "it is recommended to use BLOW function when AC is OFF" because it "helps to keep the indoor coil dry and prevent dust and mold accumulation". Neither of the two error tables in the manual, the inverter table and the fixed-speed table, lists 05 as a code.
Updated October 2026 · Cross-referenced with Godrej service manual
Indian context
The BLOW run earns its keep in India. Through the monsoon and in coastal cities such as Mumbai, Chennai, Kochi and Kolkata, the indoor coil of a split AC condenses a lot of water in every run, and a coil left wet overnight is where the musty smell at the next morning's start comes from. Letting the fan dry the coil for 5 minutes after switch-off is the cheapest way to keep that smell away, which is why Godrej fits the function, recommends using it when the AC is off, and lists the resulting 05 display under things that are not a problem. If you do turn it off, make a habit of running the AC in Fan mode for a few minutes before switching off during the humid months instead. Godrej's customer care line, from the manual, is 1800 209 5511.
What error 05 means
"05" on a Godrej split air conditioner is not an error code. Godrej's own split AC owner's manual (both the edition for model GSC 12ITC3-WUA hosted on godrejenterprises.com and the 2024 wall-mounted split AC owner's manual) covers it in the section headed "IF IT HAPPENS, IT IS NOT A PROBLEM", in the row: "After AC is switched off, if indoor display shows '05' — It may happen that you have selected the BLOW function when AC was ON, and therefore AC is performing BLOW operation after it turned OFF." The remote-controller section of the same manual describes the BLOW button: "If bad odor is coming from the air conditioner, press BLOW button on the remote handset. This function will keep the indoor fan running at super high fan speed for 5 minutes, after this the air conditioner is turned OFF. The indication of minutes will be displayed on the displayer." So 05 is the minute count of that drying run: the AC has been switched off, the indoor fan is running on at high speed to dry the evaporator coil, and the display shows the minutes remaining, starting at 05. The manual adds that "it is recommended to use BLOW function when AC is OFF" because it "helps to keep the indoor coil dry and prevent dust and mold accumulation". Neither of the two error tables in the manual, the inverter table and the fixed-speed table, lists 05 as a code.
Why error 05 happens on a Godrej Air Conditioner
On a Godrej Air Conditioner, error 05typically resolves to one of three root-cause categories. They’re ordered cheapest-to-verify first — start at the top and only escalate if the first cause is ruled out.
- Mechanical: blockage, obstruction, or worn moving part. A common cause across Godrej Air Conditioners in India — air filters clog and fan bearings and drain lines collect dust and sludge. Our step-by-step fix below targets this category first because it’s the cheapest to verify and resolvereports.
- Electrical: voltage spike, sensor fault, or PCB anomaly. India’s grid carries more voltage fluctuation than many appliance design tolerances assume, and a routine surge or sag can be enough to throw 05. If you’ve had recent voltage events (lights flickering, AC tripping), start your investigation here. A working stabilizer prevents this entire category.
- Software / configuration: stuck child-lock, demo-mode, or pending firmware reset.Less common but the cheapest fix when it applies — a 60-second factory reset clears it. We list this last because it’s rarely the actual cause, but check it before disassembling anything.
Safety first
Step-by-step fix
- 1
Step 1
Confirm it is 05 after switch-off, with the fan still running
The manual's description is specific: the AC has been switched off, the indoor display shows 05, and the indoor fan is running on at high speed with the compressor and outdoor unit off. If that matches what you see, you are looking at the BLOW drying run, not a fault, and the number on the display is the minutes remaining. If instead the AC is switched on and shows an E or F code and refuses to cool, look that code up; 05 is not in either of Godrej's error tables.
Pro tip: The BLOW button is described on the inverter remote-controller page of Godrej's manual, alongside TURBO and the temperature keys.
- 2
Step 2
Let the 5-minute run finish
Leave the AC alone. The manual says the function keeps the indoor fan running at super high speed for 5 minutes and then turns the air conditioner off, with the minutes shown on the display. The purpose, in the manual's words, is to keep the indoor coil dry and prevent dust and mould accumulation, which matters in a humid Indian room because a coil left wet is where the musty smell at the next start comes from.
Pro tip: Do not switch off the MCB to force it to stop; you lose the benefit and gain nothing.
- 3
Step 3
Turn BLOW off if you do not want the after-run
Switch the AC on with the remote, press the BLOW button once so the function is deselected, and switch the AC off again. The next time you switch off, the fan should stop with the compressor and 05 should not appear. If you cannot find the button, the remote-controller pages of your manual list it with the remote's other keys.
Caution: If the display shows 05 while the AC is running and cooling normally, or shows it together with another code, that is not the behaviour the manual describes; note it and ask Godrej service.
- 4
Step 4
If the fan never stops or the display never clears
The manual gives the BLOW run a fixed length of 5 minutes. If the indoor fan keeps running for much longer than that after switch-off, or 05 stays on the display without counting down, switch the AC off at the MCB for 5 minutes and switch it back on, then switch off with the remote and watch again. If the fan still does not stop, call Godrej customer care on 1800 209 5511 with the model number; that is a control fault, not the BLOW function.
Pro tip: Mention to the technician that the display shows 05 and the fan runs on; that detail separates a stuck relay from a normal after-run.
When to call a technician
- • The indoor fan keeps running long after the 5-minute BLOW run should have ended and 05 never clears, even after a 5-minute MCB reset.
- • 05 appears while the AC is on and cooling, or together with an E or F code.
- • The AC will not switch off from the remote at all.
Fixed it? Protect it next time. See an extended warranty plan for your Air Conditioner →
Common mistakes Godrej Air Conditioner owners make with error 05
These six anti-patterns turn a routine 30-minute fix into a costly repair or warranty void. Read before starting.
- Forcing a stuck door, lid, or panel. Prising open a Godrej Air Conditioner housing while it is in a fault state. Forcing it usually breaks the latch or sensor — turning a small part replacement into a full service call. If the door won’t open, run the safety-disconnect step first, then try again.
- Repeated unplug-and-replug as a “reset” ritual. Cycling power three or four times without diagnosing the underlying cause stresses the PCB and can convert a soft fault into a permanent firmware-corruption code. Reset once, observe whether the error returns immediately, then move to actual diagnosis if it does.
- Pouring water (or any liquid) into electronics-adjacent areas to flush a blockage.Even a small amount near the PCB or main wiring harness can cause permanent damage that voids warranty. The unit’s drainage paths exist for a reason; if a blockage isn’t cleared by the manual procedure, it isn’t getting cleared by improvisation either.
- Skipping the safety-disconnect step.“I’ll just check quickly” is the most expensive sentence in appliance repair. Working live on a 230V circuit (especially with a hot or wet appliance) carries real shock risk and instantly voids any warranty claim. Disconnect, wait two minutes for capacitor drain, then proceed.
- Buying counterfeit replacement parts on Amazon.in. Red flags: price below 60% of Godrej authorised price, generic packaging without a model-compatibility list, seller name that doesn’t match a known Godrej parts distributor, listings dated within the last 30 days with no reviews. Counterfeit parts often work for 2-3 weeks then fail with a different error, costing you double.
- Calling an “independent” technician for a warranty-covered unit. Indian appliances under Godrej warranty must be serviced by authorised technicians or the warranty voids permanently. Even if the warranty is expired, third-party local technicians often replace working parts to inflate the bill — verify each part swap by asking to see the failure on the old part before they install the new one.
Preventing future 05 on your Godrej Air Conditioner
The fix above resolves the current instance. These five maintenance habits prevent it from coming back, specific to Godrej Air Conditioners in Indian operating conditions (hard water, voltage variability, monsoon humidity).
- Monthly: wash the air filters and clear the drain line. Hard-water deposits and everyday debris are a frequent cause of recurring 05 in India, and a few minutes each month is the cheapest way to avoid a repeat.
- Quarterly: descale water-touching components. Use food-grade citric acid or a Godrej approved descaler for hard-water regions (Bangalore, Hyderabad, large parts of Maharashtra and Tamil Nadu). Skipping this in a hard-water zone shortens the life of the heating and water-touching parts.
- Run the unit through a working stabilizer. A mainline stabilizer sized for Air Conditioners is the cheapest protection against voltage-induced 05 occurrences. The MCB on your distribution board is not a substitute — it trips on overload, not on under-voltage or surge.
- Decide AMC vs DIY honestly. Compare the GodrejAMC quote against what you have actually spent on service. If your unit is >5 years old and you’ve had two service calls in the last 18 months, an AMC usually pays for itself. Younger units with no service history: DIY plus stabilizer is cheaper.
- Watch monthly for early-warning signs. Unusual noise during a specific cycle phase, water spotting, mild burning smell — any of these means a service call within a week, not a wait-and-see month. Catching 05-precursor symptoms early turns a major repair into a routine maintenance visit.
If error 05 returns within 30 days of completing the fix above, escalate directly to Godrejauthorised service — repeat patterns within a month indicate a deeper fault (worn bearing, failing PCB, leak that wasn’t fully identified) that surface-level repair won’t resolve. Document the dates and circumstances of each occurrence; the service centre will use this to prioritize root-cause investigation.
Frequently asked questions
Is 05 an error code on a Godrej AC?
No. Godrej's owner's manual lists it under "If it happens, it is not a problem": after the AC is switched off, 05 on the indoor display means the BLOW function was selected and the AC is running the BLOW operation (drying the coil) after being turned off. Neither error table in the manual contains 05.
Why does my Godrej AC keep running after I switch it off?
Because BLOW is selected. The manual says the function keeps the indoor fan running at super high speed for 5 minutes after switch-off to dry the coil, and the display shows the minutes remaining, which is why you see 05.
How do I stop the 05 and the fan running after switch-off?
Switch the AC on, press the BLOW button on the remote so the function is deselected, then switch off. The after-run and the 05 display will not appear the next time you switch off.
Is it bad to leave BLOW on?
No. Godrej's manual recommends using BLOW when the AC is off because it keeps the indoor coil dry and prevents dust and mould accumulation. The cost is 5 minutes of fan-only running after each switch-off.
The display shows 05 but the AC is on and cooling. Is that normal?
That is not the situation the manual describes; the manual's 05 appears after switch-off during the BLOW run. If you see 05 while cooling, or alongside another code, note it and ask Godrej service.
People also ask
What does 05 mean on a Godrej Air Conditioner?
How do I turn off 05 on my Godrej AC?
Why does my Godrej AC show 05 and keep the fan running after switch-off?
Is 05 in the Godrej AC error code list?
Related repair guides
Editor’s take
Most of the codes on this site mean something has gone wrong. 05 on a Godrej AC is the pleasant exception: it is the machine counting down a job you asked it to do. The confusion is understandable. The display looks like every other two-character code the AC can show, it appears exactly when you expect the unit to go quiet, and the fan keeps turning at high speed as if the remote had been ignored. Godrej's manual deals with it in one row of the "If it happens, it is not a problem" table and in the description of the BLOW button, which is where the detail lives: 5 minutes of indoor fan at super high speed after switch-off, minutes shown on the display, purpose to keep the coil dry and stop dust and mould collecting on it. That purpose is worth taking seriously. An evaporator coil comes out of a cooling run wet, and in a humid Indian room a wet coil sitting in the dark grows exactly the mould that makes the first minute of the next run smell of old socks. Five minutes of fan dries it. The electricity cost is trivial and the benefit, in smell and in coil hygiene, is real, so the advice here is the same as the manual's: leave BLOW on, especially through the humid months, unless the noise genuinely bothers you at night. If it does, the fix is one button press with the AC on, not a service call. The only time 05 deserves a call is when the behaviour stops matching the manual: a fan that runs for far longer than 5 minutes, a display that never counts down, or 05 appearing while the AC is cooling. Those are control faults wearing the same two digits, and a technician should look at them.