Air Conditioner

ALL BRANDS

Air Conditioner Error Codes India

66 fault codes across 10 brands — step-by-step fixes with safety warnings and tool links.

66

Error codes

10

Brands covered

31 min

Avg. fix time

29%

Beginner-friendly

About air conditioner errors in India

Air conditioner error codes spike during Indian summers (March-June) when AC usage peaks. Voltas leads AC error searches in India, followed by Samsung, LG, and Haier. Common faults include outdoor unit fan failures, refrigerant pressure drops (often misdiagnosed as gas leaks), and sensor errors from dust buildup on the evaporator coil. Split ACs need the outdoor unit cleaned every 3-4 months in dusty Indian cities. Most AC errors require intermediate skill and a basic multimeter — never work on a running outdoor unit.

Common air conditioner fault patterns

not cooling

45 codes

sensor fault

4 codes

motor / fan / magnetron fault

3 codes

not draining / drainage fault

1 codes

unbalanced load / spin fault

1 codes

Browse by brand

All air conditioner error codes

E6

Blue StarError E6 on a Blue Star split or inverter AC indicates a communication failure between the indoor unit and the outdoor unit — the two boards can no longer 'talk' to each other over the interconnecting signal wire.

25 min · intermediate

F2

Blue StarError F2 on a Blue Star split or inverter AC indicates a fault in the indoor coil temperature sensor — the thermistor clipped to the evaporator coil that tells the board how cold the coil is.

30 min · intermediate

E1

Blue StarError E1 on a Blue Star split air conditioner signals a fault in the indoor air temperature sensor (thermistor).

30 min · intermediate

E2

Blue StarError E2 on a Blue Star split air conditioner indicates a fault in the indoor evaporator coil temperature sensor.

35 min · intermediate

E3

Blue StarError E3 on a Blue Star split air conditioner indicates a fault with the outdoor condenser coil temperature sensor.

40 min · intermediate

E5

Blue StarError E5 on a Blue Star split air conditioner indicates that the compressor overcurrent protection circuit has tripped.

20 min · intermediate

F1

Blue StarError F1 on a Blue Star split air conditioner indicates a fault or corruption in the EEPROM (Electrically Erasable Programmable Read-Only Memory) chip on the indoor unit's PCB.

15 min · beginner

F3

Blue StarError F3 on a Blue Star split air conditioner indicates that the outdoor fan motor has failed or is not functioning within acceptable parameters.

25 min · intermediate

E1

CarrierError E1 on a Carrier split air conditioner signals a fault with the indoor ambient temperature sensor (thermistor).

30 min · intermediate

E2

CarrierError E2 on a Carrier split AC indicates a fault with the indoor evaporator (coil) temperature sensor.

40 min · intermediate

E4

CarrierError E4 on a Carrier split air conditioner indicates a fault with the outdoor condenser temperature sensor.

45 min · intermediate

E5

CarrierError E5 on a Carrier split AC indicates compressor overcurrent or overload protection has triggered.

20 min · intermediate

E6

CarrierError E6 on a Carrier split AC indicates a communication failure between the indoor and outdoor units.

35 min · intermediate

F1

CarrierError F1 on a Carrier split AC indicates an EEPROM (Electrically Erasable Programmable Read-Only Memory) fault on the indoor unit PCB.

25 min · intermediate

A1

DaikinError A1 on a Daikin AC means the system has detected an internal fault on the indoor unit's main printed circuit board (PCB).

15 min · intermediate

A3

DaikinError A3 on a Daikin AC indicates that the condensate drain system has failed — either the drain pump has malfunctioned, the drain pipe is blocked, or the condensate collection tray has overflowed.

30 min · beginner

A5

DaikinError A5 on a Daikin AC is a protection trip, not a broken part.

40 min · beginner

E1

DaikinError E1 on a Daikin air conditioner indicates a communication failure on the indoor unit's printed circuit board (PCB).

25 min · intermediate

E5

DaikinError E5 on a Daikin AC indicates that the compressor's overload protection has activated.

30 min · intermediate

E7

DaikinError E7 on a Daikin AC means the indoor unit's fan motor has stopped, stalled, or is not reaching the speed commanded by the PCB.

20 min · intermediate

H6

DaikinError H6 on a Daikin inverter AC means the outdoor board has lost position-detection feedback from the inverter compressor — it can no longer sense the rotor's position, so it cannot drive the compressor.

15 min · advanced

L3

DaikinError L3 on a Daikin AC indicates that the outdoor unit's electrical box or inverter components have reached a critically high temperature.

35 min · intermediate

U0

DaikinError U0 on a Daikin AC indicates the refrigerant pressure in the system has dropped below the safe operating threshold.

10 min · beginner

U4

DaikinError U4 on a Daikin AC indicates a communication failure between the indoor and outdoor units.

20 min · intermediate

UF

DaikinError UF on a Daikin AC means the system has not finished pairing the indoor and outdoor units correctly — the wiring and refrigerant piping do not match up, or the interconnecting cabling and address setup are wrong, or the refrigerant charge is short.

20 min · intermediate

E1

HaierError E1 on a Haier split air conditioner indicates a fault with the indoor unit air temperature sensor.

30 min · intermediate

E2

HaierError E2 on a Haier split air conditioner indicates a fault with the indoor evaporator coil temperature sensor.

30 min · intermediate

E5

HaierError E5 on a Haier air conditioner indicates voltage protection has tripped: the input AC voltage is outside the safe operating range (typically below 180 V or above 250 V).

30 min · beginner

F1

HaierError F1 on a Haier split air conditioner indicates a fault with the indoor unit fan motor.

45 min · intermediate

F2

HaierError F2 on a Haier split air conditioner indicates a fault with the outdoor unit fan motor.

45 min · intermediate

F4

HaierError F4 on a Haier split air conditioner indicates the compressor overload protection has tripped.

60 min · intermediate

C1

LGError C1 on LG air conditioners indicates that the indoor unit room temperature sensor (thermistor) has an open circuit or short circuit.

25 min · beginner

C5

LGError C5 on LG air conditioners indicates that the indoor pipe temperature sensor (evaporator thermistor) has an open circuit or short circuit.

30 min · intermediate

CH 05

LGError CH 05 indicates a communication breakdown between the indoor and outdoor units of your LG split air conditioner.

30 min · intermediate

CH 10

LGError CH 10 indicates a fault with the indoor unit fan motor, typically the BLDC (brushless DC) motor used in LG inverter air conditioners.

40 min · intermediate

E1

LGError E1 on LG air conditioners indicates that the high-pressure switch has tripped, meaning the refrigerant pressure in the system has exceeded safe operating limits.

35 min · beginner

E5

LGError E5 on LG air conditioners indicates an overcurrent protection fault, meaning the compressor is drawing more electrical current than the system's rated limit.

30 min · intermediate

E1

LloydError E1 on a Lloyd split air conditioner indicates a fault with the indoor unit air temperature sensor.

30 min · intermediate

E2

LloydError E2 on a Lloyd split air conditioner indicates a fault with the indoor evaporator coil temperature sensor.

30 min · intermediate

E3

LloydError E3 on Lloyd air conditioners signals a compressor failure or malfunction.

15 min · beginner

E4

LloydError E4 on a Lloyd split air conditioner points to an outdoor unit temperature sensor fault.

30 min · intermediate

Not Cooling

LloydA Lloyd air conditioner that runs but does not cool can have causes ranging from trivial to serious.

40 min · beginner

F11

PanasonicError F11 on Panasonic air conditioners indicates a communication failure between the indoor unit and outdoor unit.

25 min · intermediate

F91

PanasonicError F91 on Panasonic air conditioners indicates the voltage protection circuit has been activated due to unstable or out-of-range mains voltage.

20 min · beginner

F95

PanasonicError F95 on Panasonic air conditioners signals a compressor failure or malfunction detected by the unit's protection circuit.

15 min · beginner

C5

SamsungError C5 on a Samsung split air conditioner indicates a communication failure between the indoor unit and the outdoor compressor unit.

45 min · intermediate

E1

SamsungError E1 indicates a failure in the indoor unit temperature sensor (thermistor), which prevents the air conditioner from reading room temperature accurately.

25 min · beginner

E101

SamsungError E101 on a Samsung air conditioner indicates the indoor unit's PCB has not received any data from the outdoor unit for the timeout period (typically 4 minutes).

60 min · advanced

E458

SamsungError E458 on a Samsung air conditioner indicates the compressor overload protection has tripped.

60 min · intermediate

E466

SamsungError E466 on a Samsung inverter air conditioner indicates the DC link voltage on the inverter PCB is out of safe range.

30 min · beginner

E5

SamsungError E5 on Samsung air conditioners signals a compressor failure or compressor protection circuit activation.

15 min · beginner

E1

VoltasError E1 on a Voltas split air conditioner indicates a fault with the indoor air temperature sensor.

30 min · intermediate

E2

VoltasError E2 on a Voltas split air conditioner indicates a fault with the indoor evaporator coil temperature sensor.

30 min · intermediate

E3

VoltasError E3 on a Voltas split air conditioner indicates a fault with the outdoor unit temperature sensor (typically the outdoor coil or ambient temperature thermistor).

45 min · intermediate

E4

VoltasVoltas split AC error E4 indicates the indoor unit temperature sensor has failed or is reading erratic values.

25 min · intermediate

E5

VoltasVoltas split AC error E5 indicates a communication failure between the indoor and outdoor units.

30 min · advanced

E6

VoltasError E6 on a Voltas split air conditioner indicates a communication failure between the indoor unit and the outdoor compressor unit.

60 min · advanced

F1

VoltasError F1 on a Voltas split air conditioner indicates a fault with the indoor unit fan motor.

45 min · intermediate

F2

VoltasError F2 on a Voltas split air conditioner indicates a fault with the outdoor unit fan motor.

45 min · intermediate

F3

VoltasError F3 on a Voltas split air conditioner indicates the compressor overload protection has tripped.

60 min · intermediate

F4

VoltasError F4 on Voltas air conditioners signals a compressor malfunction or failure.

15 min · beginner

F9

VoltasError F9 on a Voltas inverter air conditioner indicates an outdoor DC fan motor fault — the outdoor condenser fan is not spinning at the speed the PCB commanded, or the board is getting no speed feedback from it.

30 min · intermediate

P0

VoltasError P0 on a Voltas air conditioner indicates voltage protection has tripped: the input AC voltage is outside the safe operating range (typically below 180 V or above 250 V).

30 min · beginner

P1

VoltasError P1 indicates Voltas Air Conditioner has detected abnormal voltage supply and activated its protection circuit.

15 min · beginner

P4

VoltasError P4 on a Voltas inverter air conditioner indicates DC voltage protection has tripped — the outdoor inverter PCB has detected that the internal DC bus voltage (the direct current produced after the incoming mains is rectified) has gone above or below its safe operating window, and it has shut the compressor down to protect the IPM module and capacitors.

25 min · beginner

Not Cooling

VoltasA Voltas air conditioner that runs but does not cool usually falls into one of a few buckets: a settings or airflow problem you can fix yourself, a voltage-protection cut that stops the compressor, or a deeper fault like low refrigerant or a compressor failure that needs a technician.

40 min · beginner

Frequently asked questions

What are the most common air conditioner error codes in India?

The most frequently searched air conditioner error codes in India include Blue Star E6, Blue Star F2, Blue Star E1, Blue Star E2, Blue Star E3. Most of these are intermediate-level fixes that take 31 minutes on average.

Which air conditioner brands have the most error codes?

Among air conditioner brands sold in India, Voltas (15 codes), Daikin (11 codes), Blue Star (6 codes) have the most documented fault codes. More error codes doesn't mean less reliable — it often means better diagnostic reporting.

Can I fix air conditioner errors myself without a technician?

29% of air conditioner error codes we cover are beginner-level fixes requiring no special tools. The remaining codes need basic tools (multimeter, screwdriver set) and intermediate mechanical comfort. Every guide includes a "when to call a technician" section so you know exactly where the DIY boundary is.

Time to replace your air conditioner?

If repair cost exceeds 50% of a new unit price, replacing is usually smarter. Compare top-rated air conditioners in India.

Best Air Conditioners 2026 →